Colt provided a MAXIM II Regenerative Thermal Oxidizer system to control the Methane emissions from natural gas Dehydrator processes and 'as produced' water storage tank vents. The RTO includes an LEL monitor, abort to atmosphere stack in the event of excessive Methane concentrations at the RTO inlet, and fully integrated DCS controls.
The RTO is designed with only 80% Thermal Efficiency due to the abundant fuel present in the process exhaust. The system will run self-sustaining without auxiliary fuel required during normal operation.